mardi 31 mars 2015

X-Form / TCE Issue 24fps -> 23.976

Cross post from DUC in the hopes to get some more eyes on this…



Hi All - Having a weird issue I hope is just operator error - hoping to confirm my workflow.



I'm making a D&E mix for a client and they want it delivered at 23.976. I made the D&E from my stems in the 24fps session. Everything was done at 24 and then converted to 23.976 in a separate session. I used the time shift plugin (audio suite) to go from 24 to 23.976.



The issue: When I take the 24fps full mix and null it against the 24fps D&E, all I get is music - perfect. Just what you would expect. When I take the 23.976 mix and null it against the 23.976 converted D&E, its WAY out of sync (up to 1200 samples) and I can hear everything - Dx, Mx, SFX. . I'm sure I'm not on varispeed in the time shift plug. I've tried it with x-form too and had similar results. X-Form got closer, but it still didn't null to just leave the music.



To confirm the 24->23.976 workflow, I took a new 24fps full mix and ran it through the time-shift plug in. I nulled this against the final delivery 23.976 full mix I sent - perfect null.



Any thoughts on this would be great. I've tried this in 10+CPTK and 11HD - same results.